Search results for "Indoor Air Quality"
showing 10 items of 37 documents
Factors affecting the choice of cooking fuel, cooking place and respiratory health in the Accra metropolitan area, Ghana.
2005
Indoor air pollution resulting from the combustion of solid fuels has been identified as a major health threat in the developing world. This study examines how the choice of cooking fuel, place of cooking and behavioural risk factors affect respiratory health infections in Accra, Ghana. About 65·3% of respondents use charcoal and 4·2% use unprocessed wood. A total of 241 (25·4%) respondents who cook had had respiratory health symptoms in the two weeks preceding the study. Household socioeconomic status and educational attainment of respondents were found to have a significant impact on respiratory health through their particular influence on the choice of cooking fuel. Households that use w…
The associations of indoor environment and psychosocial factors on the subjective evaluation of Indoor Air Quality among lower secondary school stude…
2017
Subjective evaluation of Indoor Air Quality (subjective IAQ) reflects both building-related and psychosocial factors, but their associations have rarely been studied other than on the individual level in occupational settings and their interactions have not been assessed. Therefore, we studied whether schools' observed indoor air problems and psychosocial factors are associated with subjective IAQ and their potential interactions. The analysis was performed with a nationwide sample (N = 195 schools/26946 students) using multilevel modeling. Two datasets were merged: (i) survey data from students, including information on schools' psychosocial environment and subjective IAQ, and (ii) data fr…
Control of indoor environments in heritage buildings: experimental measurements in an old Italian museum and proposal of a methodology
2005
Abstract This paper describes some results from an experiment carried out regarding a procedure to be adopted for temperature and R.H. monitoring of indoor spaces designed for exhibiting events, such as museums and similar institutions. The monitored data employed in this study has been collected by the Department di Ricerche Energetiche ed Ambientali of the Universita degli Studi di Palermo in co-operation with the Regional Gallery ''Palazzo Abatellis'' of Palermo. The study analyses a simple method for characterising the environmental quality of museums so as to ensure the optimal conservation of works of art. This methodology is based on the procedure (where thermal and hygrometry parame…
Indoor air quality of everyday use spaces dedicated to specific purposes—a review
2017
According to literature data, some of the main factors which significantly affect the quality of the indoor environment in residential households or apartments are human activities such as cooking, smoking, cleaning, and indoor exercising. The paper presents a literature overview related to air quality in everyday use spaces dedicated to specific purposes which are integral parts of residential buildings, such as kitchens, basements, and individual garages. Some aspects of air quality in large-scale car parks, as a specific type of indoor environment, are also discussed. All those areas are characterized by relatively short time use. On the other hand, high and very high concentration level…
Visually low-impacting methods for the measurement of parameters related to IAQ risk indicators in exhibition halls
2021
Microclimate for cultural heritage plays a fundamental role in the degradation process of artefacts exhibited in museums. Generally, the Indoor Air Quality (IAQ) monitoring inside museums is based on conventional measurements of thermo-hygrometry parameters and longtime averaged measurements of atmospheric pollutants’ concentration. Unfortunately, all these approaches require electric supply and are usually characterized by a noticeable visual impact on the exhibition space, which clearly negatively affects the visitors’ experience. This paper intends to revisit and discuss a methodology (and its test application on field, to estimate the risk of damage of three artefacts displayed in an ol…
Investigating energy saving potential in a big shopping center through ventilation control
2019
Abstract This paper investigates energy saving measures for the ventilation system of large shopping centers. This kind of buildings is characterized by high yearly energy consumptions, because of the high level of operating hours and the frequent use of obsolete technologies. In the analyzed case studies, three big Do It Yourself (DIY) shops, located in Italy, are considered. Two different approaches are considered, they are aimed at reducing the annual energy consumption for the indoor air exchange of the sales area. The first considered retrofit solution consists in the installation of heat recovery exchangers, reducing the energy demand for the air thermal treatment without changing the…
Investigating Energy Saving Potential in a Big Shopping Centre through Ventilation Control
2018
This work shows an example of energy saving interventions on the ventilation system of a big shopping center. This kind of buildings is characterized by high energy consumptions, because of the high level of yearly operating hours and the use of obsolete technologies. In the case study, a big Do It Yourself (DIY) shop located in the southern part of Italy is analyzed, proposing two different approaches aimed at reducing the annual energy consumption for the indoor air exchange of the sales area. In the AS-IS scenario, a centralized HVAC plant, composed by six rooftops, is installed on the roof of sales area, working with fixed airflow value. The first retrofit solution involves the installa…
Indoor Air Quality including Respiratory Viruses
2021
The detection of SARS-CoV-2 in indoor environments is a cause of increasing concern. In this study, three sampling methodologies have been used in order to collect SARS-CoV-2 and 17 other respiratory viruses in indoor air, combined with a new analytical process to analyze respiratory viruses. Different areas of an ophthalmological hospital were investigated for the presence of these airborne viruses. Moreover, indoor air quality (IAQ) parameters (carbon dioxide, CO2; carbon monoxide, CO; nitrogen dioxide, NO2; volatile organic compounds, VOCs; formaldehyde, HCHO; and particulate matter, PM) have been examined to study the relationship between IAQ and airborne viruses. All indoor air and sur…
COVID-19 Pandemic and Reduced Physical Activity: Is There an Impact on Healthy and Asthmatic Children?
2021
Physical activity (PA) has been seen to improve asthma symptoms, lung function, and quality of life, as well as to reduce airway inflammation and bronchial responsiveness. As a consequence of the COVID-19 pandemic, the minimal amount of PA recommended by the World Health Organization—i.e., about 60 min/day of moderate-to-high intensity—is difficult to achieve for many children, particularly those living in urban areas. Short-term changes in PA because of the COVID-19 pandemic may become habitual, increasing the risk of adverse asthma outcomes in children. Indeed, prolonged home confinement during the COVID-19 pandemic reduces PA levels and increases sedentary behaviors, possibly impairing i…
Indoor air quality in schools of a highly polluted south Mediterranean area
2019
This study aimed at surveying lower secondary schools in southern Italy, in a highly polluted area. A community close to an industrial area and three villages in rural areas was investigated. Indoor temperature, relative humidity (RH), gaseous pollutants (CO 2 and NO 2 ), selected biological pollutants in indoor dust, and the indoor/outdoor mass concentration and elemental composition of PM 2.5 were ascertained. Temperature and RH were within, or close to, the comfort range, while CO 2 frequently exceeded the threshold of 1000 ppm, indicating inadequate air exchange rate. In all the classrooms, median NO 2 levels were above the WHO threshold value. Dermatophagoides p. allergen concentration…